NJ Phillips 60mL Plastic Oral Drench Applicator (PAD826)

NJ Phillips 60mL Plastic Oral Drench Applicator (PAD826) is designed to administer oral-animal health products.

The applicator is Light weight, easy to use and has adjustable variable dose settings (2.5mL – 60mL) in 2.5mL increments.

Click For Technical Info & Tips For Use
0 out of 5 (0 customers reviews)

QuantityDiscountStatus
2 or more$135.00 eachAvailable
-
+

Free & Fast Shipping

Not able to be delivered to a PO box Live remotely? Please ensure a courier can reach your address. Click here for shipping info or give us a call.

This item is dangerous and requires a courier! Ensure a courier can reach your address.
Don’t worry, shipping is STILL FREE!
Click here for shipping info or give us a call.

Ordering multiple large items? They will be shipped on a skid or pallet to ensure that your items arrive safely and securely. The delivery truck will need to be unloaded with a forklift. If you do not have a forklift, please provide an address where a forklift is present.

This item is large and requires a courier! Ensure a courier can reach your address.
Don’t worry, shipping is STILL FREE!
Click here for shipping info or give us a call.

Ordering multiple large items? They will be shipped on a skid or pallet to ensure that your items arrive safely and securely. The delivery truck will need to be unloaded with a forklift. If you do not have a forklift, please provide an address where a forklift is present.

NJ Phillips 60mL Plastic Oral Drench Applicator (PAD826) NJP-ORAL-APP-60ML-PAD826 NJ Phillips

Description

NJ Phillips 60mL Plastic Oral Drench Applicator (PAD826)

  • Designed to administer oral-animal health products.
  • Variable dose settings. 2.5mL – 60mL in 2.5mL Increments
  • Light weight, easy to use.
  • Removable valves and cylinder
  • Provides easy access for cleaning.

Whats included:

  • 1 x 60mL Plastic Drencher, 2 x kink preventor springs & 1 x 1/4″ Hose Adaptor Kit.

Service kits available:

  • Major Service Kit – WX1331
  • Minor Service Kit – WX1330

 

 

Share your thoughts!

0 out of 5 stars

0 reviews

Let us know what you think...

What others are saying

There are no contributions yet.

×

Welcome back

Existing account holders please login below via Email, Google or Facebook or Click here to register your NEW FREE ACCOUNT.

Already Registered? Sign in with your email
Register for an account

Secure Checkout

You can shop with Specialist Sales online store with confidence. We have partnered with PayPal, Master and Visa Card which is provided by Braintree. Braintree payment technology accepts credit cards and electronic payments safely and securely for our customers.

Braintree transactions are processed using the 3D Secure framework to ensure your sensitive customer information and credit card processing is safe and secure. Similarly, PayPal also provides comprehensive buyer protection for your peace of mind.

Your information is safe

Specialist Sales adheres to strict industry standards for payment processing, using industry leading security protection measures including 128-bit Secure Sockets Layer (SSL) technology for secure Internet Protocol (IP) transactions, and compliance with the Payment Card Industry Data Security Standard (PCI DSS).

Continue as a Guest

Features & Benefits

  • Designed to administer oral-animal health products.
  • Designed for use with Cattle.
  • Variable dose settings. 2.5mL – 60mL in 2.5mL Increments
  • Light weight, easy to use.
  • Removable valves and cylinder.
  • Provides easy access for cleaning.

Directions Of Use

Before Drenching, always read the label:

  • Check the label on the pharmaceutical manufacturers container for dose rates, precautions, and safety information prior to use.

Use the recommended dose rate:

  • Use only the pharmaceutical manufacturers recommended rates.  Refer to the pharmaceutical manufacturers dose rate chart or specification.

Check the instrument:

  • Before each use, the nozzle should be inspected to ensure there are no sharp edges.  Should this occur, remove with file or emery paper or replace nozzle.

Drenching Instructions:

  1. Fit one end of the feed tube to the adaptor of the back pack, or to the draw off tube, if a non-collapsible container is being used.  Fix the tube by screwing the spring provided, in an anticlockwise direction over the tube and adaptor.  This will also prevent kinking of the feed tube at this point.
  2. If using a backpack with different size connection, connect large bore feed tube to the plastic adaptor, then attach plastic adaptor to the draw off cap using 1/4″ feed tube and spring.  Fit the other end of the tube to the inlet adaptor of the instrument in a similar manner.
  3. Prime the hand piece by squeezing the lever several times until an unbroken flow of liquid passes from the nozzle.  The instrument must be held vertically, with the nozzle pointed upwards to ensure the instrument is fully primed.
  4. Set the required dose by aligning the front of the piston with the dose marking on the cylinder.
  5. Before use and after priming each new container, measure the dose to ensure it is correct.

Questions and answers from customers

There are no questions yet. Be the first to ask a question about this product.

Send me a notification for each new answer.

Disclaimer: This information and product advice is not intended to be advice or recommendations for any specific use or circumstance. You should seek specialist advice before using any product. Always follow the manufacturer’s guidelines. Specialist Sales liability is limited.

Tips For Use

Calibration of the instrument: 

  • As the graduation markings on the cylinder are for reference only, check the accuracy of the instrument with a calibrated measuring cylinder.
  • To ensure repeatability, squirt 2 x 20mL doses into a calibrated glass.
  • The level of fluid should be at the 40mL mark.
  • If it is not, readjust the instrument following the steps in the directions for use, then perform the dose test again.
  • If you have problems with dose accuracy contact the manufacturer or place of purchase.

To adjust the dose:

  • Adjust the dose by turning the dose adjustor clockwise for smaller doses and anticlockwise for larger doses.
  • To set the correct dose, align the front of the black piston with the cylinder marking.

Drench Position: 

  • For best operating results the container should be at about the same height as the instrument with in use.
  • Should the container be at a much lower lever than the instrument, the refill rate will slow down between doses.

Care and Maintenance:

Before Drenching:

  • As lubricants will evaporate during storage, before using it is important to run a few drops of lubricant into the push rod, with the nozzle of the hand piece pointing downwards.
  • This will allow lubricant to run into the cylinder and lubricate the piston.
  • Ensure that all equipment is thoroughly clean before use by flushing with water.
  • Before each use, the nozzle should be inspected to ensure plating is not damaged or worn to a sharp edge.
  • Should this occur, remove with file or emery paper or replace nozzle.

After Drenching:

  • Where suspension type drenches have been used, it is advisable to flush the complete equipment with water detergent mix.
  • This should be followed by clean water.
  • Solution type drenches normally require a thorough flushing with clean water.
  • All moving parts should be lubricated before storage.

Sterilizing:

A common method of sterilization is as follows:

  1. Connect feed tube and spring to hand piece.
  2. Wrap cloth around the hand piece and place the end of the feed tube into a container of clean hot water and draw hot water into the cylinder by depressing the lever.  It is most important that the cylinder is full of water before suspending in the container.  If this is not done, the steam created by sterilizing can crack the cylinder.
  3. Remove the cloth and suspend the complete instrument by fully immersing in a container of water and boil for 10 to 20 minutes.  Note – Suspending the instrument not only makes it easier to remove, but also prevents damage should the container boil dry.  Chemical sterilization with antiseptic solutions is sometimes practiced and in such instances the recommendations of the chemical manufacturer should be followed.  Do not attempt to sterilize by autoclaving.
  4. Remove the instrument from the container, wrap cloth around the handle and pump dry.  Remove the cloth and dry hand piece.