Termidor HE Residual Termiticide

Termidor HE Residual Termiticide is for the protection of structures from subterranean termite damage and for the control of subterranean termites around domestic and commercial structures. 

Termidor HE Residual Termiticide is a highly efficient new formulation that makes it faster and easier to provide homes and other buildings with the best available in-ground protection against termites. Its advanced formulation, using the unique BASF-patented Advanced Polymer TechnologyTM, enhances the active ingredient’s movement in the soil to create a stronger, more stable and uniform protection zone.

Active Ingredient: Fipronil @ 96g/L

Click For Technical Info & Tips For Use
0 out of 5 (0 customers reviews)

QuantityDiscountStatus
2 or more$605.00 eachAvailable
-
+

Free & Fast Shipping

Not able to be delivered to a PO box Live remotely? Please ensure a courier can reach your address. Click here for shipping info or give us a call.

This item is dangerous and requires a courier! Ensure a courier can reach your address.
Don’t worry, shipping is STILL FREE!
Click here for shipping info or give us a call.

Ordering multiple large items? They will be shipped on a skid or pallet to ensure that your items arrive safely and securely. The delivery truck will need to be unloaded with a forklift. If you do not have a forklift, please provide an address where a forklift is present.

This item is large and requires a courier! Ensure a courier can reach your address.
Don’t worry, shipping is STILL FREE!
Click here for shipping info or give us a call.

Ordering multiple large items? They will be shipped on a skid or pallet to ensure that your items arrive safely and securely. The delivery truck will need to be unloaded with a forklift. If you do not have a forklift, please provide an address where a forklift is present.

Termidor HE Residual Termiticide TERMIDOR HE BASF

Description

Termidor HE Residual Termiticide

Active Ingredient: Fipronil @ 96g/L

Termidor HE Residual Termiticide is for the protection of structures from subterranean termite damage and for the control of subterranean termites around domestic and commercial structures. Termidor HE Residual Termiticide is a highly efficient new formulation that makes it faster and easier to provide homes and other buildings with the best available in-ground protection against termites. Its advanced formulation, using the unique BASF-patented Advanced Polymer TechnologyTM, enhances the active ingredient’s movement in the soil to create a stronger, more stable and uniform protection zone.

Every Termidor HE Residual Termiticide treatment is protected by the reliability and strength of the original Termidor active ingredient, Fipronil. It is non-repellent and undetectable to termites and is carried back to the nest by foraging termites who share it throughout the colony to create the powerful Termidor Transfer Effect.

Where can Termidor HE Residual Termiticide be used?

  • Pre-Construction: Chemical soil-treated zones under and around new buildings and structures.
  • Post-Construction: Chemical soil-treated zones under and around existing buildings and structures.
  • Pre & Post-Construction High-Pressure Treatments: Chemical soil treated zones around existing buildings and structures.
  • Reticulation Systems
  • Protection of poles and fence posts
  • Termite nests (trees, stumps, posts, power or utility poles, mounds)
  • Cavity, nest & active termite treatments (e.g. active workings in timber in-service, infested wall cavities, voids under concrete)

Chemical treatment for termite control around existing buildings should be considered part of an integrated approach to reduce the risk of termite attack. It should be conducted by Licensed Pest Control Operators. The steps below best describe the procedure for optimum termite management:

  • The building owner should try to minimise water entering under and around the building and improve drainage to reduce moisture accumulating in these areas.
  • Ventilation of sub-floor areas should also be optimised to reduce moisture accumulation.
  • The area under the floor should be kept free from debris-timber such as off-cuts of wood or firewood.
  • Treat with a residual chemical zone treatment such as Termidor Residual Termiticide and Insecticide or Termidor HE Residual Termiticide in compliance with AS3660.2.
  • Regular inspections should be carried out (at least annually as recommended by AS3660 Series).
  • If any additional subsequent building or landscaping work causes disruption to the chemical soil treated zone it must be restored to maintain protection.

What is the period of protection from Termidor HE Residual Termiticide?

Data currently available indicates that Termidor He, when applied as a soil treatment around or under a building or structure in accordance with this label, will be effective against subterranean termites for a minimum period of (8) eight years. Delayed mortality effects may be observed, meaning termites may live and continue to be active for several weeks after penetrating the treated zone. To re-establish the treated zone after the 8-year Period of Protection, re-application at full rates is required. The actual protection period will also be affected by factors such as termite pressure, climatic and soil conditions and subsequent soil disturbance.

As with all chemical termiticides, regular inspections (at least annually) by a competent Licensed Pest Control Operator are recommended as bridging and breaching of treated zones can occur. The need for retreatment should be determined as a result of these inspections.

The general public can purchase Termidor HE Residual Termiticide, but it should only be used by licensed pest control operators in accordance with Australian Standards.

Pack Size: 2.34-Litre

Registrant: BASF Australia LTD. (APVMA #: 80820)

Termite and White Ant control product range

Share your thoughts!

0 out of 5 stars

0 reviews

Let us know what you think...

What others are saying

There are no contributions yet.

×

Welcome back

Existing account holders please login below via Email, Google or Facebook or Click here to register your NEW FREE ACCOUNT.

Already Registered? Sign in with your email
Register for an account

Secure Checkout

You can shop with Specialist Sales online store with confidence. We have partnered with PayPal, Master and Visa Card which is provided by Braintree. Braintree payment technology accepts credit cards and electronic payments safely and securely for our customers.

Braintree transactions are processed using the 3D Secure framework to ensure your sensitive customer information and credit card processing is safe and secure. Similarly, PayPal also provides comprehensive buyer protection for your peace of mind.

Your information is safe

Specialist Sales adheres to strict industry standards for payment processing, using industry leading security protection measures including 128-bit Secure Sockets Layer (SSL) technology for secure Internet Protocol (IP) transactions, and compliance with the Payment Card Industry Data Security Standard (PCI DSS).

Continue as a Guest

Features & Benefits

  • Contains the active ingredient Fipronil in a highly effective new formulation
  • Boosted transport and effectiveness.
  • Transfer effect to nests.
  • Extra soil mobility properties.
  • 150mm decreased trench depth.
  • 600mm wide spacings.

Directions Of Use

For Termidor HE Residual Termiticide directions for use, click here

  • Termidor HE Residual Termiticide is a unique termiticide that has been developed to be applied through the Termidor High Pressure Device. 
  • The Termidor High-Pressure device allows soil injection and high-pressure injection under concrete or for conventional soil treatment, extending application intervals where drilling and injection are required.
  • The application should be conducted by Licensed Pest Control Operators:

Pest: Subterranean termites including (but not limited to) Coptotermes acinaciformis, Mastotermes darwiniensis, Schedorhinotermes spp.

Situation: 

  • Pre-Construction: Chemical soil-treated zones under and around new buildings and structures.
  • Post-Construction: Chemical soil-treated zones under and around existing buildings and structures.
  • Pre & Post-Construction High-Pressure Treatments: Chemical soil treated zones around existing buildings and structures.
  • Reticulation Systems
  • Protection of poles and fence posts 
  • Termite nests (trees, stumps, posts, power or utility poles, mounds)

Rate: 625mL in 100L Water.

Important: Refer to critical comments specific to each situation on the directions for use


Pest: Subterranean termites including (but not limited to) Coptotermes acinaciformis, Mastotermes darwiniensis, Schedorhinotermes spp.

Situation: Cavity, nest & active termite treatments (e.g. active workings in timber in-service, infested wall cavities, voids under concrete)

Rate: 6.25mL in 1L of Water.

Important: Refer to critical comments on the directions for use.


Vertical Treated Zones

  • Vertical treated zones are designed to deter termites from gaining concealed horizontal access to a building or structure. 
  • Apply at least 100L of prepared spray per cubic metre of soil. Vertical treated zones should be a minimum of 150mm wide and applied to a depth of 50 mm below the top of the footing. 
  • Where a horizontal treated zone is installed, the vertical treated zone should be installed to be continuous with it. The most effective method of creating an even and continuous treated zone is by trenching and treating the soil as it is back-filled. Soil injection equipment (rodding) must only be used where trenching and treating the back-fill is not possible or practical.

Horizontal Treated Zones  (Termidor High-Pressure Device)

  • Horizontal treated zones are to be applied to deter termites from gaining concealed vertical access to the building sub-structure.
  • Horizontal treated zones should cover all areas of soil beneath suspended floors where there is inadequate access or where there is less than 400 mm clearance. 
  • The treated zone should also be continuous beneath a concrete slab-on-ground or on-fill. 
  • The treated zone should surround any connection between the building and the soil and completely about any internal vertical treated zone around any substructure. 
  • Otherwise install perimeter treated zones around each individual pier, stump, penetration point and sub-structure wall.
  • Horizontal treated zones must have a minimum depth of 80 mm. 
  • It may be necessary to loosen the soil to allow spray solution to percolate to form the treated zone; the soil should be scarified to a depth of 50mm. 
  • Apply 2.5-5 L (according to concentration) of prepared Termidor HE Residual Termiticide spray per square metre of soil.
  • When termiticide needs to be injected through a concrete slab to create a horizontal treated zone, the application volume should be increased per square metre up to 5-10 L of spray solution (according to concentration). 
  • To ensure an even treated zone is created, it is also recommended that maximum drill spacings and minimum application volumes consistent with the following table be adopted. Use a slab injector fitted with a multi-directional tip. 
  • When applying through such structures, the rod should be held vertically at 90° to the slab and rotated during application. 
  • Ensure a strong seal with the top of the drill hole to minimise leakage and that drill holes are plugged after treatment.

Rates are a general guide only.  Before opening, carefully read Termidor HE Residual Termiticide directions for use, precautionary and protection statements, storage and disposal, safety directions and first aid instructions.  The product is designed for the particular purpose indicated on the label. Failure to use the product strictly as directed may be illegal and dangerous and render the product ineffective.

Questions and answers from customers

There are no questions yet. Be the first to ask a question about this product.

Send me a notification for each new answer.

Disclaimer: This information and product advice is not intended to be advice or recommendations for any specific use or circumstance. You should seek specialist advice before using any product. Always follow the manufacturer’s guidelines. Specialist Sales liability is limited.

Host & Pest

Host Pest
Host & Pest
Log, Post And Pole - Protection, Post - Construction, Pre - Construction, Reticulation System, Termite Nest Or Colony & Wall Cavity Treatment Subterranean Termite, Subterranean Termite - C. Acinaciformes, Subterranean Termite - Coptotermes Spp., Subterranean Termite - Schedorhinotermes, Subterranean Termite Incl. M.Darwiniensi

Tips For Use

Restraints: 

  • Do not apply if heavy rains or storms that are likely to cause runoff are forecast within 48 hours.
  • Do not apply at less than label rates.
  • Do not apply to internal surfaces.

Precautions:

  • Residents and pets should not be allowed in a room being treated. 
  • Any spills should be cleaned up before leaving the room (refer to the SDS).
  • Ensure all heating/air conditioning ducts, air vents, plumbing pipes, sewer lines, floor drains, heating pipes and electrical lines/conduits are known and identified before commencing any application of termiticide. 
  • Do not puncture or contaminate any of these.
  • Avoid application around edible plants.

Re-Entry Period

  • Do not re-enter treated areas until the spray has dried.

Mixing.

  • Half fill the spray tank with water then add the required quantity of Termidor HE. 
  • Stir, then top up the spray tank to the required volume. 
  • The use of this product in a tank mix with other insecticides is not recommended as the behaviour and efficacy of the product may be affected.
  • Ensure equipment is free of leaks and clean from residues of other chemicals before mixing.

Protection Of Wildlife, Fish, Crustaceans And Environment.

  • Highly toxic to aquatic life. 
  • Do not contaminate wetlands or water courses with this product or used containers. 
  • Rinse water and run-off from treated areas must be prevented from entering drains or waterways.

Protection Of Pets And Livestock.

  • Before spraying, remove animals and pets from the areas to be treated. 
  • Cover or remove any open food and water containers. 
  • Cover or remove (as applicable) fish ponds, aquariums, etc before spraying.

Protection Of Honey Bees And Other Insect Pollinators

  • Highly toxic to bees. 
  • The use pattern as per Direction for Use is not expected to result in exposure to bees and the risk is considered acceptable.

Storage:

  • Store in the closed, original container in a cool, well-ventilated area. 
  • Do not store for prolonged periods in direct sunlight.

Safety Directions:

  • It will irritate the eyes and skin. 
  • Repeated exposure may cause allergic disorders. 
  • Avoid contact with eyes and skin. 
  • Wash hands after use. 
  • When opening the container, preparing spray and using the prepared spray wear chemical resistant clothing buttoned to the neck and wrist and a washable hat, half-facepiece respirator with combined dust and gas cartridge and elbow-length PVC or nitrile gloves. 
  • After each day’s use, wash gloves, contaminated clothing and respirator and, if rubber, wash with detergent and warm water.

First Aid:

  • If poisoning occurs, contact a doctor or the Poisons Information Centre. Phone Australia 131 126.
  • For further information, refer to the Safety Data Sheet (SDS). 

This information and product advice is not intended as advice or recommendations for any specific use or circumstance. You should seek specialist advice before using any product. Always follow the manufacturer’s guidelines. Specialist Sales liability is limited.​

Withholding Period

Withholding Period Details (WHP):

  • Not applicable when used as directed.

SDS & Technical

Termidor HE Residual Termiticide Label APVMA Download Pdf
Termidor HE Residual Termiticide Label Download Pdf
Termidor HE Residual Termiticide Label SDS Download Pdf
Termidor HE Residual Termiticide Homeowner Brochure Download Pdf
Termidor HE Residual Termiticide TechSheet Download Pdf
Termidor HE Residual Termiticide Trial Results Download Pdf
Termidor HE Residual Termiticide Soil TechNote Download Pdf
Termidor HE Residual Termiticide Flood TechNote Download Pdf
Termidor HE Residual Termiticide & Trelona Bait Combined Brochure Download Pdf

Related Products